The Compact, Vertical Packaged (VS/VT) heat pumps are perfectly suited for applications that require ducted, forced air heating and cooling. These units fit well in tight spaces and come standard with hot water assist for up to 40% cost savings on water heating annually. The VS/VT is a smaller version of the ES5 YT, and these models are ideal for homes of any size, net-zero buildings, and more.
MODEL | VS006 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 7,200 | - |
COOLING EER | 18.6 | - |
HEATING BTU/HR | 5,600 | - |
HEATING COP | 3.7 | - |
MODEL | VS009 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 10,900 | - |
COOLING EER | 17.4 | - |
HEATING BTU/HR | 8,500 | - |
HEATING COP | 3.6 | - |
MODEL | VS012 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 11,900 | - |
COOLING EER | 18.1 | - |
HEATING BTU/HR | 9,400 | - |
HEATING COP | 3.6 | - |
MODEL | VS015 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 16,000 | - |
COOLING EER | 19.8 | - |
HEATING BTU/HR | 11,600 | - |
HEATING COP | 4.1 | - |
MODEL | VS018 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 21,700 | - |
COOLING EER | 22.2 | - |
HEATING BTU/HR | 15,400 | - |
HEATING COP | 4.0 | - |
MODEL | VS024 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 26,000 | - |
COOLING EER | 19.7 | - |
HEATING BTU/HR | 19,400 | - |
HEATING COP | 4.0 | - |
MODEL | VS030 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 30,100 | - |
COOLING EER | 18.5 | - |
HEATING BTU/HR | 22,300 | - |
HEATING COP | 3.9 | - |
MODEL | VS036 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 37,800 | - |
COOLING EER | 18.0 | - |
HEATING BTU/HR | 30,200 | - |
HEATING COP | 3.9 | - |
MODEL | VS041 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 38,700 | - |
COOLING EER | 17.1 | - |
HEATING BTU/HR | 31,100 | - |
HEATING COP | 3.6 | - |
MODEL | VS042 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 43,600 | - |
COOLING EER | 18.6 | - |
HEATING BTU/HR | 32,000 | - |
HEATING COP | 3.8 | - |
MODEL | VS048 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 50,500 | - |
COOLING EER | 17.6 | - |
HEATING BTU/HR | 39,600 | - |
HEATING COP | 3.6 | - |
MODEL | VS060 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 60,000 | - |
COOLING EER | 16.9 | - |
HEATING BTU/HR | 46,900 | - |
HEATING COP | 3.6 | - |
MODEL | VS072 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 70,100 | - |
COOLING EER | 15.1 | - |
HEATING BTU/HR | 53,200 | - |
HEATING COP | 3.3 | - |
MODEL | VT024 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 25,800 | 19,300 |
COOLING EER | 18.6 | 24.2 |
HEATING BTU/HR | 19,400 | 14,800 |
HEATING COP | 4.0 | 3.8 |
MODEL | VT030 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 32,200 | 25,500 |
COOLING EER | 18.4 | 25.8 |
HEATING BTU/HR | 24,300 | 20,000 |
HEATING COP | 3.8 | 4.2 |
MODEL | VT036 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 37,400 | 28,500 |
COOLING EER | 17.7 | 25.2 |
HEATING BTU/HR | 29,500 | 22,900 |
HEATING COP | 3.9 | 4.2 |
MODEL | VT042 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 45,900 | 35,100 |
COOLING EER | 18.5 | 26.0 |
HEATING BTU/HR | 32,400 | 25,500 |
HEATING COP | 3.9 | 4.2 |
MODEL | VT048 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 51,300 | 39,200 |
COOLING EER | 18.9 | 27.2 |
HEATING BTU/HR | 38,300 | 30,200 |
HEATING COP | 3.9 | 4.3 |
MODEL | VT060 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 60,900 | 46,500 |
COOLING EER | 17.6 | 23.6 |
HEATING BTU/HR | 46,300 | 36,600 |
HEATING COP | 3.8 | 4.2 |
MODEL | VT072 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 68,900 | 55,300 |
COOLING EER | 15.8 | 21.1 |
HEATING BTU/HR | 51,800 | 44,000 |
HEATING COP | 3.4 | 3.9 |